Home Testing Battery

Battery Test Facility

High Voltage Battery Test Facility

Our high voltage battery test facility is able to perform standard and specialized development tests on high voltage batteries in environmental and ambient test stations. Computer controlled tests are meticulously deployed by skilled personnel to fully encompass the customer’s requirements. Our automotive battery lab can conduct most SAE or DIN specification battery tests.

High Voltage Battery Test Stand
High Voltage Battery Test Stand

Battery Pack, Module, and Cell Testing

  • 3 Environmental chambers 
    • Large chamber size 102 cm x 153 cm
    • Temp range -55° C to 155° C
  • 1 Ambient test stand
  • Tests are safety and sensor monitored for hydrogen and temperature
  • Custom Labview software and Aerovironment chargers provided.
    • Vmax = 450 V
    • Imax = 265 A
    • Imin = -265 A
    • Pmax = 125 KW
    • Pmin = -125 KW

Automotive Battery Test Laboratory

  • Computer controlled system tester
  • Number of stations - 40
  • Temperature range - +70° F to +175° F  (on 10 stations)
  • Voltage range - 0 to 18 volts
  • Current range - 0 to 100 amps
Stabilizing Water Bath
Stabilizing Water Bath

High-Temperature Stabilizing Water Bath

  • 2 Baths
  • Battery capacity - 30 or 15 to each station
  • Temperature range from +70° F to +175° F

Temperature Controlled Test Chambers

  • Battery capacity - 20
  • Temperature range:  -40° F to +250° F

High Current Discharge Tester

  • Discharge current range - 0 to 1,300 amps
  • Data sample rate - 10 samples/sec

Parallel Charger

  • 20 stations
  • Charge voltage range - 0 to 18 volts
  • Charger current capacity -0 to 25 amps